<?xml version="1.1" encoding="utf-8"?>
<article xsi:noNamespaceSchemaLocation="http://jats.nlm.nih.gov/publishing/1.1/xsd/JATS-journalpublishing1-mathml3.xsd" dtd-version="1.1" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><front><journal-meta><journal-id journal-id-type="publisher-id">JCNR</journal-id><journal-title-group><journal-title>Journal of Clinical and Nursing Research</journal-title></journal-title-group><issn>2208-3685</issn><eissn>2208-3693</eissn><publisher><publisher-name>Bio-Byword Scientific Publishing Pty. Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.26689/jcnr.v9i11.12875</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title>A Case of Medical Damage Identification of Balloon Rupture and Retention Complicated with Acute Ischemic Stroke</title><url>https://artdesignp.com/journal/JCNR/9/11/10.26689/jcnr.v9i11.12875</url><author>LiuZhijie,SongJianwen</author><pub-date pub-type="publication-year"><year>2025</year></pub-date><volume>9</volume><issue>11</issue><history><date date-type="pub"><published-time>2025-12-05</published-time></date></history><abstract>Percutaneous transluminal angioplasty and endovascular stenting have become very important methods for the treatment of carotid artery stenosis and vertebrobasilar artery stenosis. In this case, the patient suffered from balloon rupture during the operation, with the tip of the balloon catheter retained and fixed on the stent in the subclavian artery segment, and subsequent acute ischemic stroke complicated by balloon rupture and retention. This is a rare type of device and operation-related complication. Through this case, a detailed analysis of the faults and deficiencies in the diagnosis and treatment of balloon rupture during interventional surgery is conducted, in order to provide a reference for solving similar problems.</abstract><keywords/></article-meta></front><body/><back><ref-list><ref id="B1" content-type="article"><label>1</label><element-citation publication-type="journal"><p>Liu X, Xu G, Zhang R, 2003, Interventional Therapy for Cerebrovascular Diseases. 2nd ed. Beijing: People’s Medical Publishing House, 91–92.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B2" content-type="article"><label>2</label><element-citation publication-type="journal"><p>Wholey M, Al-Mubarek N, Wholey M, 2003, Updated Review of the Global Carotid Artery Stent Registry. Catheter Cardiovasc Interv, 60(2): 259–266.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B3" content-type="article"><label>3</label><element-citation publication-type="journal"><p>Liu D, Li B, Liu B, et al., 2022, A Case of Retrieving an Incarcerated Coronary Guidewire Using a Guidezilla Extension Catheter Combined with a Post-Dilation Balloon. Chinese Journal of Interventional Cardiology, 30(05): 396–397.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B4" content-type="article"><label>4</label><element-citation publication-type="journal"><p>Deng W, Zhou P, 2023, A Case Report of Microguidewire Rupture during Mechanical Thrombectomy for Acute Cerebral Infarction. Stroke and Nervous Diseases, 30(01): 76–77.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B5" content-type="article"><label>5</label><element-citation publication-type="journal"><p>Liu J, Ma H, 2019, Empirical Research on Medical Product Infringement Cases. China Health Law, 27(03): 12–15.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B6" content-type="article"><label>6</label><element-citation publication-type="journal"><p>Xia W, 2022, Interpretation and Implementation of the “Guidelines for Forensic Identification of Medical Damage”. Journal of Forensic Medicine, 38(02): 143–149.</p><pub-id pub-id-type="doi"/></element-citation></ref></ref-list></back></article>
