<?xml version="1.1" encoding="utf-8"?>
<article xsi:noNamespaceSchemaLocation="http://jats.nlm.nih.gov/publishing/1.1/xsd/JATS-journalpublishing1-mathml3.xsd" dtd-version="1.1" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><front><journal-meta><journal-id journal-id-type="publisher-id">JERA</journal-id><journal-title-group><journal-title>Journal of Electronic Research and Application</journal-title></journal-title-group><issn>2208-3502</issn><eissn>2208-3510</eissn><publisher><publisher-name>Bio-Byword Scientific Publishing Pty. Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.26689/jera.v8i4.7930</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title>Integrated Experimental and Simulation Investigation of Breakdown Voltage Characteristics Across Electrode Configurations in SF6 Circuit Breakers </title><url>https://artdesignp.com/journal/JERA/8/4/10.26689/jera.v8i4.7930</url><author>GuanBo,YuQi,YuanQingpeng,ChenShiwen,ChenLailin,GuoSu,ZhuPeilong</author><pub-date pub-type="publication-year"><year>2024</year></pub-date><volume>8</volume><issue>4</issue><history><date date-type="pub"><published-time>2024-08-13</published-time></date></history><abstract>This study investigates the breakdown voltage characteristics in sulfur hexafluoride (SF6) circuit breakers, employing a novel approach that integrates both experimental investigations and finite element simulations. Utilizing a sphere-sphere electrode configuration, we meticulously measured the relationship between breakdown voltage and electrode gap distances ranging from 1 cm to 4.5 cm. Subsequent simulations, conducted using COMSOL Multiphysics, mirrored the experimental setup to validate the model’s accuracy through a comparison of the breakdown voltage-electrode gap distance curves. The simulation results not only aligned closely with the experimental data but also allowed the extraction of detailed electric field strength, electric potential contours, and electric current flow curves at the breakdown voltage for gap distances extending from 1 to 4.5 cm. Extending the analysis, the study explored the electric field and potential distribution at a constant voltage of 72.5 kV for gap distances between 1 to 10 cm, identifying the maximum electric field strength. A comprehensive comparison of five different electrode configurations (sphere-sphere, sphere-rod, sphere-plane, rod-plane, rod-rod) at 72.5 kV and a gap distance of 1.84 cm underscored the significant influence of electrode geometry on the breakdown process. Moreover, the research contrasts the breakdown voltage in SF6 with that in air, emphasizing SF6’s superior insulating properties. This investigation not only elucidates the intricate dynamics of electrical breakdown in SF6 circuit breakers but also contributes valuable insights into the optimal electrode configurations and the potential for alternative insulating gases, steering future advancements in high-voltage circuit breaker technology.</abstract><keywords/></article-meta></front><body/><back><ref-list><ref id="B1" content-type="article"><label>1</label><element-citation publication-type="journal"><p>Lin X, Zhang J, Xu J, et al., 2022, Dynamic Dielectric Strength of C3F7CN/CO2 and C3F7CN/N2 Mixtures in High Voltage Circuit Breakers. IEEE Transactions on Power Delivery, 37(5): 4032–4041.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B2" content-type="article"><label>2</label><element-citation publication-type="journal"><p>Ou X, Wang L, Liu J, et al., 2020, Numerical Simulation of Streamer Discharge Development Processes with Multi-Component SF6 Mixed Gas. Physics of Plasmas, 27: 073504.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B3" content-type="article"><label>3</label><element-citation publication-type="journal"><p>Jiang X, Li X, Zhao H, et al., 2013, Analysis of the Dielectric Breakdown Characteristics for a 252-kV Gas Circuit Breaker. IEEE Transactions on Power Delivery, 28(3): 1592–1599.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B4" content-type="article"><label>4</label><element-citation publication-type="journal"><p>Guo Z, Liu S, Pu Y, et al., 2019, Study of the Arc Interruption Performance of CO2 Gas in High-Voltage Circuit Breaker. IEEE Transactions on Plasma Science, 47(5): 2742–2751.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B5" content-type="article"><label>5</label><element-citation publication-type="journal"><p>Xiao D, 2016, Insulation Characteristics of Sulfur Hexafluoride (SF6). in: Gas Discharge and Gas Insulation. Springer Berlin, Heidelberg, 195–229.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B6" content-type="article"><label>6</label><element-citation publication-type="journal"><p>Okubo H, Yamada T, Hatta K, et al., 2002, Partial Discharge and Breakdown Mechanisms in Ultra-Dilute SF6 and PFC Gases Mixed with N2 Gas. Journal of Physics D: Applied Physics, 35: 2760–2765.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B7" content-type="article"><label>7</label><element-citation publication-type="journal"><p>Xiao D, 1999, Research on Discharge Characteristics of the Avalanche in SF6 Gas Mixtures, thesis, Xi’an Jiao Tong University.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B8" content-type="article"><label>8</label><element-citation publication-type="journal"><p>Geng J, Yang J, Shu T, et al., 2023. Stability of Breakdown Phenomenon in N2, SF6, and their Mixture under Impulse Voltages. AIP Advances, 13: 035033.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B9" content-type="article"><label>9</label><element-citation publication-type="journal"><p>Liu W, Yang A, 2011, Unsupervised Learning Algorithm for Finite Mixture Model Based on BIC Criterion and Gibbs Sampling. Acta Electronica Sinica, 39: 134–139.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B10" content-type="article"><label>10</label><element-citation publication-type="journal"><p>Krämer W, 1998, Fractional Integration and the Augmented Dickey-Fuller Test. Economics Letters, 61: 269–273.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B11" content-type="article"><label>11</label><element-citation publication-type="journal"><p>Ito T, Bulger M, Pazin MJ, et al., 1997, ACF, an ISWI-Containing and ATP-Utilizing Chromatin Assembly and Remodeling Factor. Cell, 90(1): 145.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B12" content-type="article"><label>12</label><element-citation publication-type="journal"><p>Zhou Z, Han D, Zhao M, et al., 2020, Review on Decomposition Characteristics of SF6 Alternative Gases. Transactions of China Electrotechnical Society, 35(23): 4998–5014.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B13" content-type="article"><label>13</label><element-citation publication-type="journal"><p>Kapetanovic M, 2011, High Voltage Circuit Breakers. Sarajevo.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B14" content-type="article"><label>14</label><element-citation publication-type="journal"><p>Jia SL, Zhao H, Li XW, et al., 2011, Survey of Recent Researches on the Arc Quenching Characteristics of SF6 Substitute Gases. High Voltage Apparatus, 47(11): 87–91 + 97.</p><pub-id pub-id-type="doi"/></element-citation></ref></ref-list></back></article>
