<?xml version="1.1" encoding="utf-8"?>
<article xsi:noNamespaceSchemaLocation="http://jats.nlm.nih.gov/publishing/1.1/xsd/JATS-journalpublishing1-mathml3.xsd" dtd-version="1.1" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><front><journal-meta><journal-id journal-id-type="publisher-id">SSR</journal-id><journal-title-group><journal-title>Scientific and Social Research</journal-title></journal-title-group><issn>2661-4332</issn><eissn>2981-9946</eissn><publisher><publisher-name>Bio-Byword Scientific Publishing Pty. Ltd.</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.26689/ssr.v6i11.8817</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title>Operational Strategy of Nonuniform Air Supply in Cleanrooms</title><url>https://artdesignp.com/journal/SSR/6/11/10.26689/ssr.v6i11.8817</url><author>WangXin,ZhangMinwei,LiHao,WangLi,LiJun,ZouZhijun</author><pub-date pub-type="publication-year"><year>2024</year></pub-date><volume>6</volume><issue>11</issue><history><date date-type="pub"><published-time>2024-11-29</published-time></date></history><abstract>To ensure that cleanroom cleanliness requirements are met, the current design and operation of cleanrooms generally necessitate the fan filter unit (FFU) to open. However, deploying an excessive number of FFUs may lead to an air volume redundancy problem, which can reduce air volume. Conversely, reducing FFUs and their airflow might also increase the risk of uneven indoor airflow distribution and particle concentration. This study analyzes the influence of the nonuniform operational strategy of FFUs (including the opening rate, arrangement position, and air velocity of FFUs) on the distribution of airborne particulate matter concentration in the cleanroom using CFD simulation technology. Results showed that opening only the top part of the source FFU can significantly reduce the indoor particulate concentration in the cleanroom and maintain the cleanliness that meets the requirements of cleanrooms. In the case of the same number of air exchanges, increasing the air velocity of the upper FFU of the indoor airborne particulate pollution source has a significant effect on the purification of indoor particulate matter in the cleanroom. These results show that the nonuniform air supply from the upper FFU of the source has good purification performance for airborne particles in a typical cleanroom.</abstract><keywords/></article-meta></front><body/><back><ref-list><ref id="B1" content-type="article"><label>1</label><element-citation publication-type="journal"><p>Sun W, 2017, ASHRAE Design Guide for Cleanrooms: Fundamentals, Systems, and Performance. ASHRAE, Atlanta, 448.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B2" content-type="article"><label>2</label><element-citation publication-type="journal"><p>Chalk S, 2013, New Challenges to the Cleanroom Paradigm for Multi-product Facilities. BioPharm International, 26(5): 38–47.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B3" content-type="article"><label>3</label><element-citation publication-type="journal"><p>May GS, Spanos CJ, 2006, Fundamentals of Semiconductor Manufacturing and Process Control. John Wiley &amp; Sons, New Jersey.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B4" content-type="article"><label>4</label><element-citation publication-type="journal"><p>Khoo CY, Lee CC, Hu SC, 2012, An Experimental Study on the Influences of Air Change Rate and Free Area Ratio of Raised-floor on Cleanroom Particle Concentrations. Building and Environment, 2012(48): 84–88.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B5" content-type="article"><label>5</label><element-citation publication-type="journal"><p>Xu T, 2004, Considerations for Efficient Airflow Design in Cleanrooms. Journal of the IEST, 47(1): 24–28.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B6" content-type="article"><label>6</label><element-citation publication-type="journal"><p>International Organization for Standardization, 2015, Cleanrooms and Associated Controlled Environments—Part 1: Classification of Air Cleanliness. ISO 14633-1: 2015, 1999.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B7" content-type="article"><label>7</label><element-citation publication-type="journal"><p>Chen J, 2021, Airflow Motion Distribution and Cleanliness Recovery Characteristics in the Pharmaceutical Cleanroom, thesis, Hunan University of Technology.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B8" content-type="article"><label>8</label><element-citation publication-type="journal"><p>Shao J, 2013, Investigation on Effects of Structure Parameters of Plenum Chamber on Outlet Flow Field Uniformity, thesis, Dalian University of Technology.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B9" content-type="article"><label>9</label><element-citation publication-type="journal"><p>Yang Y, 2022, Study on the Effect of Various Return Air Modes on the Particle Concentration Distribution by the Orifice Plate Air Supply in the Clean Room, thesis, Tianjin University of Commerce.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B10" content-type="article"><label>10</label><element-citation publication-type="journal"><p>Tao S, Li S, Kou B, et al., 2022, Analysis on the Influence of FFU and Raised Floor Layout on Air Flow in Semiconductor Clean Room. Contamination Control &amp; Air-Conditioning Technology, 2022(5): 108–112.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B11" content-type="article"><label>11</label><element-citation publication-type="journal"><p>Shao X, Liang S, Zhao J, et al., 2021, Experimental Investigation of Particle Dispersion in Cleanrooms of Electronic Industry under Different Area Ratios and Speeds of Fan Filter Units. Journal of Building Engineering, 2021(43): 102590.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B12" content-type="article"><label>12</label><element-citation publication-type="journal"><p>Shao X, Hao Y, Liang S, et al., 2022, Experimental Characterization of Particle Distribution during the Process of Reducing the Air Supply Volume in an Electronic Industry Cleanroom. Journal of Building Engineering, 2022(45): 103594.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B13" content-type="article"><label>13</label><element-citation publication-type="journal"><p>Whyte W, Whyte WM, Ward S, 2018, Ventilation Effectiveness in Cleanrooms and its Relation to Decay Rate, Recovery Rate, and Air Change Rate. European Journal of Parenteral and Pharmaceutical Sciences, 23(4): 126–134.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B14" content-type="article"><label>14</label><element-citation publication-type="journal"><p>Loomans MGLC, Molenaar PCA, Kort HSM, et al., 2019, Energy Demand Reduction in Pharmaceutical Cleanrooms through Optimization of Ventilation. Energy and Buildings, 2019(202): 109346.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B15" content-type="article"><label>15</label><element-citation publication-type="journal"><p>Yang L, Huang C, 2014, Study on Characteristics and Two Zone Model of Multi Air Distribution for Cleanroom. Contamination Control &amp; Air-Conditioning Technology, 2014(1): 5–9.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B16" content-type="article"><label>16</label><element-citation publication-type="journal"><p>Yin J, Liu X, Guan B, et al., 2021, Performance Analysis and Energy Saving Potential of Air Conditioning Systems in Semiconductor Cleanrooms. Journal of Building Engineering, 2021(37): 102158.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B17" content-type="article"><label>17</label><element-citation publication-type="journal"><p>Zhuang C, Shan K, Wang S, 2021, Coordinated Demand-controlled Ventilation Strategy for Energy-efficient Operation in Multi-zone Cleanroom Air-conditioning Systems. Building and Environment, 2021(191): 107588.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B18" content-type="article"><label>18</label><element-citation publication-type="journal"><p>Liang S, Liu Y, Shao X, et al., 2022, Particle Distribution Characteristics of Electronic Industry Clean Room with Different FFU Air Volume. Building Energy Efficiency, 50(1): 96–101.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B19" content-type="article"><label>19</label><element-citation publication-type="journal"><p>China National Standards, 2013, GB 50073: Code for Design of Clean Room.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B20" content-type="article"><label>20</label><element-citation publication-type="journal"><p>Zhao J, Shao X, Li X, et al., 2021, Theoretical Expression for Clean Air Volume in Cleanrooms with Non-uniform Environments. Building and Environment, 2021(204): 108168.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B21" content-type="article"><label>21</label><element-citation publication-type="journal"><p>Elsaey AAE, Fouad MA, 2023, Numerical Investigation of using FDCU on Temperature Distribution in Non-Unidirectional Cleanrooms. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 105(1): 15–30.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B22" content-type="article"><label>22</label><element-citation publication-type="journal"><p>Zhang F, Fan Y, Liu J, et al., 2022, Study on Human Particle Emission Rates of Cleanrooms. Journal of HV &amp; AC, 52(10): 168–173.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B23" content-type="article"><label>23</label><element-citation publication-type="journal"><p>Zhou L, Sun W, Huang C, et al., 2017, Studies on Comparison of Particle Concentration Models for Cleanroom. Procedia Engineering, 2017(205): 3308–3315.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B24" content-type="article"><label>24</label><element-citation publication-type="journal"><p>Fluent Inc., 2006, F.L.U.E N.T. User’s Guide. Fluent Inc., Lebanon.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B25" content-type="article"><label>25</label><element-citation publication-type="journal"><p>Yang C, Yang X, Xu T, et al., 2009, Optimization of Bathroom Ventilation Design for an ISO Class 5 Clean Ward, in Building Simulation. Springer Berlin, Heidelberg, 133–142.</p><pub-id pub-id-type="doi"/></element-citation></ref><ref id="B26" content-type="article"><label>26</label><element-citation publication-type="journal"><p>Liu Z, Zhu H, Song Y, et al., 2022, Quantitative Distribution of Human Exhaled Particles in a Ventilation Room, in Building Simulation. Tsinghua University Press, Beijing, 1–12.</p><pub-id pub-id-type="doi"/></element-citation></ref></ref-list></back></article>
